GAS TESTING EQUIPMENT EMISSION MONITORING TEST SUPPORT

 

Microprocessor Control

Advanced Gas Analyzers

2-Year Warranty Support

   
 

SIGNAL USA offers a full range of CEMS and emission monitoring support equipment for environmental compliance and process monitoring applications. Gas Dividers and Pre-diluters, NOx Generators/NOx Converter Testers and Zero Air Generators manually and remotely controlled versions.

gas analyzers
Gas
Analyzers
 
 
 
 
 
 
   

 


CALIBRATION GAS DIVIDER

MODEL 821S
10-Step Gas Divider
The Model 821S allows instrument operators and manufacturers to check the linearity of their instruments, by the use of only one calibration gas and one diluent. Eleven fixed steps from 0-100% concentration are provided, each step rising by 10% The unit operates the method of dividing two gases through a chain of 10 identical capillary tubes, in such a way that the operator selects the number of capillaries to which each gas is open. The Model 821S has a repeatability performance of +/-0.5% of point, and when used in conjunction with the Model 852V5SP Pre Diluter, gases of up to 1,000 times greater in concentration can be used.

   


CALIBRATION GAS PRE-DILUTER

MODEL 852V5SP for 2 Gas Inlets
MODEL 853V5SP for 3 Gas Inlets
These Models can be used either to dilute 2 or 3 gases or to increase the versatility or the Model 821S Gas Divider. When using the Pre-Diluter, the calibration gas to be diluted, and the diluent gas are connected to the rear of the unit, at a pressure of 50psi. A 20- turn counting dial and a flow meter on the front panel, allow the percentage dilution to be set. Each unit is supplied with its own logarithmic calibration curve for the purpose of correctly setting the dilution. The units are temperature controlled to 40 deg C, and can be supplied with remote controlled servo kit and D to A converter.

   

NH3 AND NOX CONVERTERS FOR GAS ANALYZERS
MODEL 410 (NH3) and MODEL 420 (NOx) CONVERTERS
This compact 3U high 19” rack enclosure houses both the NH3 to NO converter as well as a self contained heated filter and calibration gas selection valve. It is generally used with Chemiluminescent NOx analysers such as Signal’s Model 4000VM.

   


NOX CONVERTER TESTER

MODEL Noxgen 3A and MODEL Noxgen 3R
The Model Noxgen 3 series allows instrument operators and manufacturers to check the converter efficiency of their Chemiluminescent NOx analysers.
The unit is controlled by using two decade thumbwheel switches adjustable from 00 to 99, and a three position ozone level switch for low, medium and high settings. The Noxgen 3 R provides the option of remote control using TTL levels for all operational functions

   

ZERO AIR SUPPLY
MODEL AS80
The Model AS80 catalytic air purifier is designed to provide an inexpencive source of clean, zero-grade air for flame ionization detectors (FID). The unit removes all hydrocarbons, including methane, down to 0.1% of original level. Up to 10 FID units can be run from one unit. The AS80 contains a high temperature furnace containing alumina pellets coated in platinum. this oxidises all combustible compounds to CO2 and H2O. The unit can completely remove methane at rates of up to 5 l/min high efficiency and up to 20 l/min medium efficiency.

 

   

Interested sales representatives in all regions of the U.S. should contact us.

   

 

 

SIGNAL USA
355 North York Rd.
Willow Grove, PA 19090
Tel: 215.830.8882
Fax: 215.830.8922
Toll free: 1-866-SIGNAL-U

Hours of operation:
M-F 8AM to 6PM
weekends and 24-hour emergercy service by agreement
email: sales@k2bw.com

© 1996-2007 SIGNAL USA Rights Reserved

 

 

 

continuous emission monitoring system gas analysis support equipment, supplies and service